An IT8 target is a slide of known colours. Scan it, compare the result with its measurements, and you have a description of your scanner's errors. That is all a profile is, and it is worth knowing where it stops.
Every scanner sees colour a little wrongly, and each one is wrong in its own way. Colour management for film scanning is the business of measuring that error and cancelling it. The instrument is an IT8 target: a piece of transparency film printed with patches of known colour. Scan the target, compare what the scanner reported with what the patches actually are, and software can write a profile that corrects every later scan. The idea is simple. Its limits are less well understood, and they matter most for exactly the material archives care about: old, faded and unusual film.
What is an IT8 target?
IT8 is the name of a group of standards from the American National Standards Institute dealing with colour communication in the graphic arts. Two of them define input targets for scanners.
| Standard | Target type | Used to profile |
|---|---|---|
| IT8.7/1 | Transmissive, on colour transparency film | Film scanners, flatbeds in transparency mode, camera-scanning rigs |
| IT8.7/2 | Reflective, on colour photographic paper | Flatbed scanners for prints and documents |
The layout is the same for both: 264 colour patches and 24 grey patches, 288 in all, arranged in 22 columns. Twelve columns step through hue, saturation and lightness. Further columns carry scales of cyan, magenta, yellow and black, then red, green and blue. The last three columns are left to the manufacturer. The grey scale runs along the bottom from the film's lightest to its darkest density. The international equivalent of the standard is ISO 12641, and software sometimes specifies which edition of it a target must follow.
Targets are made in film sizes from 35mm slide upwards. Kodak's version was sold under the name Q-60; other manufacturers and independent suppliers have made their own. Each is produced in batches, and each batch is measured.
How does a target become a profile?
Three things are needed: the target, its reference file and profiling software.
- Scan the target with every automatic correction switched off, at the settings that will be used for real work.
- Load the reference file. This lists the measured colour values of each patch for that manufacturing batch. Using the wrong batch file builds the wrong profile.
- Let the software compare the two. The differences between what the scanner recorded and what the patches measure become a table of corrections, saved as an ICC profile.
- Apply the profile to later scans and convert to, or embed, a standard working space in the saved file.
Many scanning programs have this routine built in. The Canadian Heritage Information Network's guide gives a way to judge the outcome: when the aim is to preserve the original's colour, it suggests a mean colour distance between the profiled scan and the reference of roughly 3 to 8. It adds a diagnostic. If the errors after profiling are larger at the dark and light ends than in the middle, the scanner probably lacks the density range for the film.
What does a scanner profile actually fix?
It fixes the device. Each scanner has its own lamp, filters and sensor, and reports colour in its own way; a profile translates those reports into standard colour values. Filmscanner.info, a long-running German test site, estimates that calibration takes a typical scanner from roughly 80 per cent colour fidelity to about 95 per cent.
That gain is real and repeatable, and it has a consequence that is easy to miss: the profile belongs to one machine. Two scanners of the same model can differ, so a profile made on one should not be copied to the other. It also belongs to one set of conditions. Lamps change with warm-up, temperature and age, so profiles need renewing. The same site suggests about once a month for occasional users and daily for critical reproduction work.
Profiling is also only half of colour management. The other half is the monitor. A scan judged on an uncalibrated screen is being compared with nothing in particular, which is why scanning guides insist on calibrating the display with a measuring device and why FADGI describes a controlled viewing environment, with a 5,000 K lightbox for the film, as critical for transparencies.
What can a profile not fix?
Quite a lot, and the US federal digitisation guidelines (FADGI, third edition, May 2023) are frank about it. "Profiling a scanner will not assure FADGI compliance or accurate color reproduction," they state, and profiling cannot restore colour or detail that is no longer there.
- Scanner limits. Dynamic range, sharpness and resolution are properties of the hardware. A profile cannot add shadow detail the sensor did not record. The image histogram tool will show whether shadows have clipped.
- Faults in the photograph. Under-exposure, a colour cast from mixed lighting or a filter are part of the original, and a correct scan reproduces them.
- Fading. A profile assumes the film's dyes behave like the target's dyes. Faded film does not. The scan will still be an accurate record of the slide's present state, which is the purpose of a master file. Putting the colour back is a different operation, discussed in restoring faded colour slides digitally.
- Negatives. IT8 targets are positives. Filmscanner.info notes that the orange mask and higher contrast of negative film make IT8 calibration unworkable, and FADGI observes that calibration targets for negatives are scarce and that midtones have to be set manually.
Why does the film type of the target matter?
A scanner separates colour through three filters, and different dye sets interact with those filters differently. The closer the target's dyes are to the dyes in the film being scanned, the better the profile fits. FADGI's instruction is to profile with the closest available target, and it singles out one case: Kodachrome needs a Kodachrome target, because one made on Ektachrome is inadequate. Kodachrome's dyes were formed during processing and are unlike those of E-6 films.
For an archive this is a practical problem as well as a technical one. Targets on discontinued films are no longer made, existing ones are ageing, and a collection may contain stocks for which no target ever existed. The realistic approach is to profile on a current E-6 target, state that fact in the project documentation, and treat it as the declared basis of the scans. Filmscanner.info reports that even a single target used for all film types produces a noticeable improvement over none.
Targets are film, so they fade like film. The same source advises against relying on a target more than about twenty years old, and recommends cold, dry, dark storage, the regime described in how to store slides and transparencies for the long term.
Do camera-scanning rigs need profiling too?
Yes, and the method is the same: photograph the target on the light source used for the film, with the working lens, aperture and white balance, and build a profile from the result. The profile then describes the combination of sensor, lens and light. Change the light panel and the profile is void. Camera scanning film: a practical set-up guide covers the rest of the rig.
A working routine for colour-managed scanning
- Calibrate the monitor with a measuring device and keep the room dim and neutral.
- Profile the scanner or camera rig with an IT8.7/1 target on the nearest available film type, using the batch's own reference file.
- Record the target, its batch, the date and the software in the project log.
- Scan with automatic corrections off, apply the profile, and embed a standard working space in each master.
- Re-profile on a schedule and whenever anything changes.
- Keep corrections for fading or taste out of the master. Make them on copies, where tools such as the white balance correction tool are appropriate.
The choice of working space, where published standards differ, is covered in scanning medium-format transparencies.
Colour management and the Robert Harper archive
The principal analogue format in the Robert Harper Photograph Library is 6 x 7 colour transparency film, within 52,684 unique analogue photographs counted by the archive's inventory, which has not been checked frame by frame against the physical material. Colour is central to the subjects recorded there, which include jewellery, fragrance, fashion and food. The inventory does not name film stocks, so the choice of profiling target is a question for the scanning stage, to be answered from the film itself. More than half of the archive is still on film and has yet to be scanned.
The holdings are described in the analogue collections and listed in the archive inventory. Imaging vendors who document their colour management are invited to make contact through the digitisation partners page.
Frequently asked questions
What is an IT8 target?
It is a standardised chart of colour patches used to calibrate scanners. The film version, defined by ANSI IT8.7/1, is a piece of transparency film carrying 264 colour patches and a 24-step grey scale, supplied with a reference file listing the measured colour of each patch on that batch. Scanning it lets software build an ICC profile for the scanner.
Do I need an IT8 target to scan slides?
Not to get pleasant results, but you do if you want the scan to match the slide in a way that can be repeated and documented. Without a profile, colour depends on the scanner's built-in assumptions. With one, the scanner's errors are measured and corrected. For archive work, profiling is part of being able to state what the files represent.
Can an IT8 profile fix faded slides?
No. A profile corrects the scanner, not the film. A faded slide scanned through a good profile is an accurate record of a faded slide, which is exactly what a preservation master should be. Correcting the fading is a separate step, done on a copy, and it involves judgement about what the original colours were.
Can you profile a scanner for colour negatives with IT8?
Not in the standard way. IT8 targets are positives, and negative films differ in orange mask and contrast from one stock to another, so a single profile cannot describe them. Negatives are captured as transparent film without clipping and then inverted with software designed for the purpose, which makes film-specific corrections during inversion.
How often should a scanner be re-profiled?
Whenever the light source, software or settings change, and at regular intervals in between, because lamps drift with age and temperature. Scanner specialists suggest monthly for occasional users and far more often for critical colour work. Targets age too, since they are dye images themselves, so store them cold, dry and dark and replace old ones.
Sources
- Wikipedia: IT8
- Filmscanner.info: Scanner calibration with IT-8 targets
- Image Science: IT8 targets for scanner profiling
- FADGI: Technical Guidelines for Digitizing Cultural Heritage Materials, third edition (May 2023)
- Canadian Heritage Information Network: How to Scan Photographic Transparencies and Photographic Negatives
Published by Archive.London. Corrections are welcome under our editorial policy.